Quickgene
01 / Services

Peptide characterization services

Choose single-method testing or a combined characterization study for GLP-1 and related metabolic peptides. We confirm the study question, controls and reporting scope with you.

Request a Technical Assessment
02 / Service packages

Individual methods and integrated studies

Single method

SV-AUC Study

Sedimentation velocity AUC

Solution-state species distribution, oligomer or aggregation trends, and orthogonal follow-up to SEC.

Single method

CD Study

Circular dichroism, far- & near-UV

Compare spectral profiles between test and reference samples and study formulation or temperature effects.

Single method

cIEF Study

Capillary isoelectric focusing

Measure pI and charge-peak distribution. Compare lots, formulations or stressed samples.

Single method

Bioactivity / Potency Assay

Cell-based luciferase reporter gene assay

Assess responses at GLP-1R, GIPR or GCGR and report relative potency when the reference comparison supports it.

Recommended

Integrated Package

AUC + CD + cIEF + Bioassay, one report

Agree common sample identifiers and comparison conditions, then combine the selected methods, results and study limitations in one report.

Deliverables by method

We confirm the deliverables and reporting range for your sample and scope during technical assessment.

SV-AUC · Sedimentation coefficient distribution
c(s) profile
SV-AUC · Species distribution
Relative signal fractions for resolved species
SV-AUC · Sedimentation coefficient
s20,w (standard conditions)
SV-AUC · Molecular weight
Solution-state estimate
CD · Far-UV (190–250 nm)
Secondary structure spectrum
CD · Composition
α-helix / β-sheet estimate
CD · Near-UV
Tertiary structure fingerprint
CD · Thermal transition
Apparent transition temperature, where suitable
cIEF · Isoelectric point
pI determination
cIEF · Charge variants
Acidic / basic variant ratios
cIEF · Peak distribution
Relative peak areas with integration notes
Report · Interpretation
Integrated cross-method analysis
Bioassay · Dose response and potency
Fitted curve parameters and relative potency where suitable
Bioassay · Receptor panel
GLP-1R / GIPR / GCGR CRE-luciferase
Report · Data package
Methods, raw data, figures
Report · Documentation
Applicable guidance and project records, as agreed
Study design · Formulation
Buffer / excipient screening
Study design · Comparability
Pre/post-change protocols

Discuss your sample and study goals

Share the molecule name or code, sample format, concentration, buffer and the question you want to answer. We can discuss the method, sample amount, reporting scope and timeline.